Structures Laboratory Testing Rates (From December 2021) |
||||
Sr. # |
Category |
Test Description |
Normal Rates* (Rs.) |
Sample Requirements |
1 |
Concrete Mix Design |
Mix Design without Admixture and SRMs. a) Cement b) Sand c) Coarse aggregate |
50,000 |
5 bags |
15 cubic ft. |
||||
30 cubic ft. |
||||
2 |
Mix Design with OPC and Admixtures. a) Cement b) Sand c) Coarse aggregate |
100,000 |
5 bags |
|
15 cubic ft. |
||||
30 cubic ft. |
||||
3 |
Mix Design with Admixture, SRMs, and special chemicals. a) Cement b) Sand c) Coarse aggregate |
150,000 |
5 bags |
|
15 cubic ft. |
||||
30 cubic ft. |
||||
4 |
Special Mix design |
Depends on the site and the extent of work. |
Depends on the site and the extent of work. |
|
5 |
Compressive Strength Test |
Compressive Strength Test (Cube/Cylinder) |
1,000 (Per sample) |
3 Samples Per Test |
6 |
Compressive Strength Test (Bricks) |
1,000 (Per sample) |
3 Samples Per Test |
|
7 |
Compressive Strength Test (Hollow/Solid Block) |
1,500 (Per sample) |
3 Samples Per Test |
|
8 |
Cement Test |
Initial Setting Time of Cement |
1500 (Per sample) |
10 Kg Per Test |
9 |
Final Setting Time of Cement |
1500 (Per sample) |
10 Kg Per Test |
|
10 |
Consistency Test (Water Demand of Cement) |
1500 (Per sample) |
10 Kg Per Test |
|
11 |
Soundness Test of Cement |
1500 (Per sample) |
10 Kg Per Test |
|
12 |
Blaine Fineness Test of Cement |
5000 (Per sample) |
1 Kg Per Test |
|
13 |
Compressive Strength of Cement using mortar cube a) Sand b) Cement |
7500 (For Single Day Compressive Strength)
|
1375 g Per Day
|
|
1 kg Per Day |
||||
14 |
Tensile Test |
Rebar Tensile Test (Up to 1-inch Diameter) |
1400 (Per sample) |
2 Samples Per Test (460mm) |
15 |
Rebar Tensile Test (Above 1-inch Diameter) |
2000 (Per sample) |
2 Samples Per Test (460mm) |
|
16 |
Rebar Bend Test (Up to 1-inch Diameter) |
800 (Per sample) |
1 Samples Per Test (250mm) |
|
17 |
Bend Test (Above 1–inch Diameter) |
1200 (Per sample) |
1 Sample Per Test (250 mm) |
|
18 |
Tensile Test (7 Wire Stand) |
5000 (Per sample) |
2 Samples Per Test (590 mm) |
|
19 |
Tensile Test (Bolts) |
2500 (Per sample) |
2 Samples Per Test |
|
20 |
Sieve Analysis |
Sieve Analysis of Coarse Aggregates |
1200 |
10 Kg Per Test |
21 |
Sieve Analysis of Fine Aggregates |
1200 |
10 Kg Per Test |
|
22 |
Fineness Modulus (Coarse & Fine Aggregates) |
1400 |
10 Kg Per Test |
|
23 |
Aggregate Testing |
Specific Gravity of Aggregates |
2000 |
10 Kg Per Test |
24 |
Water Absorption of Aggregates |
2000 |
10 Kg Per Test |
|
25 |
Crushing Value of Coarse Aggregates |
3000 |
10 Kg Per Test |
|
26 |
Impact Value of Coarse Aggregates |
3000 |
10 Kg Per Test |
|
27 |
Water Absorption Test |
Water Absorption Test (Block/Brick) |
2000 (Per sample) |
3 Samples Per Test |
28 |
Block Testing |
Density (Block/Cube/Cylinder) |
500 (Per sample) |
3 Samples Per Test |
29 |
Core Extraction |
On-site Core Test Extraction |
14000 Per Core (Ferro scanning is not included) |
– |
30 |
NDT |
Non-Destructive Testing (Rebound Hammer, Ultrasonic Test, Depth Meter, Corrosion) |
Depends on the site and the extent of the work, to be decided after a field visit by the testing team.**
|
Depends on the site and the extent of the work, to be decided after a field visit by the testing team.**
|
31 |
Structure Level Testing |
Testing of Bridges under static and dynamic load test. |
||
32 |
Load test to check the adequacy of existing structures. |
*These rates are for normal testing; multiply these rates by the following factors for witness and urgent tests.
Test Mode |
Normal |
Witness |
Urgent |
Factors |
1x |
1.5x |
2.5x |
Report Time |
5 working days |
5 working days |
2 working days |
Time Slot |
– |
It will be given according to the lab’s testing schedule, provided no academic activities are going on. |
It will be given according to the lab’s testing schedule, provided no academic activities are going on. |
**The client will provide transport and accommodation.
Note: Academic activities/ institutional duties will be given first priority.
Contact us for more information and availability of time slot